Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9211471

- Product Categories
- Friendly Links
- home > Supply > High and low voltage electroscope the the ↓ ↓ to supply River Ruineng electroscope the ↑ ↑ sound and light electroscope rain electroscope ↑ ↑
High and low voltage electroscope the the ↓ ↓ to supply River Ruineng electroscope the ↑ ↑ sound and light electroscope rain electroscope ↑ ↑
Information Name: | High and low voltage electroscope the the ↓ ↓ to supply River Ruineng electroscope the ↑ ↑ sound and light electroscope rain electroscope ↑ ↑ |
Published: | 2013-03-15 |
Validity: | 180 |
Specifications: | Complete |
Quantity: | 99999.00 |
Price Description: | |
Detailed Product Description: | The Company's operating the GSY type electroscope, quality assurance, welcome to consult the discussion. Product categories: electrical safety equipment → electroscope Series → high-pressure electroscope → GD-35KV high voltage the electroscope product name: AC high-voltage sound and light electroscope Specifications: GSY type 10KV similar product specifications: the GSY type 10KV high voltage electroscope, GSY type 35KV high voltage electroscope GSY 110KV high voltage electroscope the GSY type 220KV high voltage electroscope GSY type 500KV high voltage electroscope. AC high voltage sound and light electroscope, high-pressure high-pressure electroscope electroscope Overview Overview The high pressure the electroscope, also known as high pressure measured electrical. The main types of emitting high-pressure the electroscope, sound and light high-pressure electroscope. The luminous type high-pressure electroscope by the handle, retaining ring, fastening screws, parts of the window of neon, neon tubes and metal probe (hook). The high pressure electroscope Note: (1) First, determine the high-pressure the electroscope rated voltage must be adapted to the voltage levels of the electrical equipment under test, so as not to endanger the personal safety of the operator or misjudgment. (2) examine the electrical operator with insulated gloves, holding a part below the retaining ring, while the designated persons guardianship. Should be the same in the electrical equipment to verify the the electroscope performance intact, and then examine the electrical equipment to detect. Note that the operation electroscope gradually toward the device closer to the process and, if so luminous voice instructions, examine the electrical immediately stop. (3) the use of high-pressure electroscope, the climate is good, in order to ensure the safety of the operating personnel. (4)) examine the electrical body charged body should maintain a sufficient safety distance 10KV voltage below safe distance should be more than 0.7m. (5) electroscope should conduct a preventive tests every six months. Two high-pressure electroscope use and precautions high-pressure electroscope use methods and precautions to ensure the safety of personnel and equipment, to ensure the integrity of the electroscope, The electroscope should be stored in air circulation, dry environment places. Cope electroscope before the self-test, examine the electrical operation: press the test button that examine the electrical indicator should send a clear audible and visual alarm signal. If the self-test the silent light indicating signal shall examine the electrical operation. Electrical inspection must check before ground deflectors is intact, the point of contact is reliable. Third, examine the electrical sequence of operations: 1 ground deflectors ground rolling, reliable folder on good ground rail or pole. Ground deflectors top plug inserted into the jack of the first section of the rod end. The 3 spin posterior power indicator, and a self-test test. 4 Tensile all insulated operating rod, it pull enough and positioning. 5 operating personnel should be on the The electroscope electric parts electrical testing to prove the good performance of the electroscope, and then examine the electrical construction site, to confirm whether the construction site electric, 6 Finally, it should reply to the electrical parts of reinspection to ensure the integrity of the electroscope. The high-pressure electroscope the structure and use of high-pressure electroscope structure and the use of high-pressure electroscope is mainly used to test equipment to voltage above 250V high-voltage electrical equipment. At present, widely used in light emitting type, the type of sound and light, the three types of windmill. They are generally by the detection part (the indicator part or windmill), insulating parts, handshake part of three major components. The insulation part refers to the self-part screws until the cover retaining ring ended the indicator lower metal convergence, shaking hands part of the the part refers hood below the retaining ring. Wherein the insulating portion, the handshake part is different according to the voltage level of its length is not the same. Must first examine the electrical use of high-pressure electroscope conscientiously perform operations guardianship, one person to operate a guardianship. Operator former guardian after. Using the electroscope, you must pay attention to the fit of the rated voltage and the voltage level of the measured electrical equipment, otherwise, could endanger the personal safety of the operating personnel or cause misjudgment. Examine the electrical, the operator must wear insulated gloves, wear insulated boots prevent Kuabudianya or contact voltage damage to the human body. The operator should hand to cover the following handshake part of the retaining ring, first electric equipment inspection. The examination should be gradually moved closer to energized equipment to the light emitting or audible only to verify the integrity of the electroscope. Then need to be detected on the electric inspection device. Same pole of the erection of a multilayer wiring electrical testing, should be a priori low pressure, posterior high pressure, a priori lower posterior upper. Need of special note, before the use of high-pressure electroscope examine the electrical, be sure to carefully read the manual, check the test whether the super-cycle, the appearance is damaged, tetanus. Example, GDY type high-voltage wind electroscope removed from the package, should first observe whether electric turn indicator blades with off-axis, whether the alarm is audible, off-axis are not allowed to use, and then the electric turn indicator in the hands gently shaking, its blade should be a slight swing to prove good, then check the alarm part proved sound good. For the GSY type series high-voltage sound and light electroscope should indicator perform a self-test test before the operation, to rotate the indicator the operating rod fixed in the operating rod, and stretch to the provisions of length, and then as a self-test to . Note that the high-pressure electroscope can not detect the DC voltage. Custody and transport, not to the high-pressure electroscope strong vibration or impact, no unauthorized adjustment disassembly, where rain and snow affect the insulating properties of the environment must not be used. High-pressure electroscope on the open-air sun exposure, should be kept in a dry and well-ventilated place, do not use with corrosive chemical solvent and detergent to wipe or contact. 4, how to use 35kV high voltage electroscope how to use electrical inspection 35kV high pressure electroscope inspection of electricity? A: The high-pressure electroscope is used to detect the high-voltage overhead line cable lines, high-voltage electrical equipment charged. 35kV, high-pressure electroscope should be used: (1) whether the same attention to the high-pressure electroscope with the line voltage is detected. (2) Check the high-pressure electroscope is intact. (3) examine the electrical wear insulated gloves, holding a part of the cover retaining ring following outdoors should wear insulated boots. Guardian, the first known electric high-voltage lines or equipment testing should sound and light show as normal. (4) Then, in the to be detected on the line equipment for detection. Detection equipment should slowly moved closer, until contact contact conductive part. In this process, as has been silent, light indication, can be judged without electricity; otherwise, sound and light indication, can be known charged. Related Products: electroscope Series: the electroscope (electroscope specifications models), high-pressure electroscope exchange electroscope, high-voltage AC electroscope, high-voltage sound and light electroscope, the exchange of high-pressure electroscope sound and light high-pressure electroscope telescopic sound and light Electroscope, Pocket electroscope folding electroscope, retractable sound and light high and low voltage electroscope. |
Admin>>>
You are the 20411 visitor
Copyright © GuangDong ICP No. 10089450, The Shijiazhuang REpower Power Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 20411 visitor
Copyright © GuangDong ICP No. 10089450, The Shijiazhuang REpower Power Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility